DOLD UG 6960 Multifunctional Safety Timer

UG 6960 combines a defined safety input function with selectable delay behavior and both instantaneous and delayed safety contacts. DOLD offers application variants for functions such as emergency stop, safety gates, light curtains and two-hand control. These variants are not one interchangeable universal input circuit: the full ordering code determines the function, monitoring and timing range.
Key Specifications
Construction width | 22.5 mm |
Supply example | 24 VDC; specify full ordering code |
Contact arrangement | 2 instantaneous NO and 2 delayed NO safety contacts |
Monitoring | Separate semiconductor monitoring outputs; not substitutes for safety contacts |
Timing | Five selectable delay functions; available ranges depend on variant |
Safety inputs | Specified E-stop, gate, light-curtain, two-hand or other variant |
Safety capability | Up to PL e / Category 4 and SIL 3 within documented conditions |
Applications and Industries
Timed industrial safety sequences with a defined input circuit and validated stopping or access-release requirement.
Industrial automation
Review Summary
Consider UG 6960 for a compact, hardware-configured safety sequence where the required delay is established by the machine design. Its rotary selection avoids a programmable-controller project, but time-function selection, wiring and validation remain engineering tasks. A timer does not measure actual standstill.
Price and Configuration
Request a quote for the selected configuration,quantity and delivery schedule. Confirm the exact model,options,integration scope and support terms.