DOLD SAFEMASTER S Motion Monitors

DOLD SAFEMASTER S covers standstill, speed and frequency monitoring through sensor-based and sensorless variants. The described sensorless standstill method evaluates remanent motor voltage, while other configurations use proximity-switch or encoder information.
Key Specifications
Family functions | Standstill, speed and frequency monitoring |
Sensor-based choices | Compatible proximity switches or encoder signals |
Sensorless standstill | Remanent motor-winding voltage evaluation |
Sensorless frequency scope | Specified drive-voltage/frequency monitoring variants |
Example standstill model | UG 6946 |
Example frequency model | UH 6937 |
Maximum family safety scope | Up to Category 4/PL e and SIL 3; model/function conditions apply |
Applications and Industries
CNC and machine tool control
Metalworking and machine tools
Review Summary
A relevant monitoring family when permission for access or reduced-motion operation depends on an accepted drive state. Choose the exact measurement method and supported motor configuration; electrical-frequency monitoring and measured shaft speed should not be assumed identical in every mechanism.
Price and Configuration
Request a quote for the selected configuration,quantity and delivery schedule. Confirm the exact model,options,integration scope and support terms.