Balluff BNI0098 PROFIsafe over IO Link Safety Hub Overview
BNI0098, designation BNI IOF-329-P02-Z038, is a Balluff safety hub using PROFIsafe over IO-Link. It connects specified protective inputs and outputs through a compatible supported architecture; ordinary IO-Link transport alone does not make any attached device safety-rated.
Key Specifications
Product detail | Specification |
Manufacturer | Balluff |
Model | Balluff BNI0098 PROFIsafe over IO Link Safety Hub |
Reviewed code | BNI0098 / BNI IOF-329-P02-Z038 |
Interface | PROFIsafe over IO-Link 1.1 |
Safe I/O reference | Manufacturer lists 12 safe inputs and 2 safe outputs |
Connections | Specified 5-pin and 8-pin M12 device connectors |
Enclosure | IP67 under documented connection conditions |
Qualification scope | Manufacturer PL e, Category 4 and SIL3 device claims; complete architecture governs |
Review Summary

Consider BNI0098 when the complete controller/master/hub configuration supports the required protective devices. Verify the exact firmware, wiring and safety parameters, then calculate and validate the whole response chain rather than using the hub's timing figure as machine stopping time.
Price and Availability
Request a quote for the selected configuration and delivery schedule. Any published reference price applies only to its stated configuration and is not a store checkout price.