DOLD SAFEMASTER S Motion Monitors
DOLD SAFEMASTER S Motion Monitors
DOLD SAFEMASTER S covers standstill, speed and frequency monitoring through sensor-based and sensorless variants. The described sensorless standstill method evaluates remanent motor voltage, while other configurations use proximity-switch or encoder information.
Review Summary
A relevant monitoring family when permission for access or reduced-motion operation depends on an accepted drive state. Choose the exact measurement method and supported motor configuration; electrical-frequency monitoring and measured shaft speed should not be assumed identical in every mechanism.
Family functions Standstill, speed and frequency monitoring Sensor-based choices Compatible proximity switches or encoder signals Sensorless standstill Remanent motor-winding voltage evaluation Sensorless frequency scope Specified drive-voltage/frequency monitoring variants Example standstill model UG 6946 Example frequency model UH 6937 Maximum family safety scope Up to Category 4/PL e and SIL 3; model/function conditions apply Applications and Industries
CNC and machine tool control
Metalworking and machine tools
Request a quote for the exact configuration,quantity and delivery schedule.
| Family functions | Standstill, speed and frequency monitoring |
| Sensor-based choices | Compatible proximity switches or encoder signals |
| Sensorless standstill | Remanent motor-winding voltage evaluation |
| Sensorless frequency scope | Specified drive-voltage/frequency monitoring variants |
| Example standstill model | UG 6946 |
| Example frequency model | UH 6937 |
| Maximum family safety scope | Up to Category 4/PL e and SIL 3; model/function conditions apply |