LAPP OLFLEX 190 Industrial Control Cable Review: Specs, Price and Applications
Updated: 7 days ago
OLFLEX 190 is LAPP's oil-resistant multi-conductor power and control cable family for industrial equipment. The unshielded 190 and shielded 190 CY are separate choices; conductor configuration and installation ratings must be checked by article number.
Quick Verdict
Evaluate OLFLEX 190 for an industrial control or power route that matches the exact article's electrical, environmental and installation limits. Select shielding deliberately, and do not treat installation flexibility as evidence of a continuous-motion duty rating.
LAPP OLFLEX 190 Industrial Control Cable at a Glance
Reviewed family: OLFLEX 190 industrial power and control cable
Jacket reference: Oil-resistant PVC family construction
Screening distinction: 190 CY is the shielded companion; confirm full product name
Electrical selection: Conductor size/count and circuit requirements govern article selection
Installation evidence: Verify applicable jacket markings and current article datasheet
Motion scope: Confirm permitted movement; continuous flex or torsion cannot be assumed
Price: Request a quote for the exact ordering configuration.
Technical Specifications
Specification | Documented configuration |
Reviewed family | OLFLEX 190 industrial power and control cable |
Jacket reference | Oil-resistant PVC family construction |
Screening distinction | 190 CY is the shielded companion; confirm full product name |
Electrical selection | Conductor size/count and circuit requirements govern article selection |
Installation evidence | Verify applicable jacket markings and current article datasheet |
Motion scope | Confirm permitted movement; continuous flex or torsion cannot be assumed |
Design and Build
The directory image shows a braided shield and belongs to the 190 CY construction. The main 190 designation does not itself specify that shield. Keep the distinction visible in the bill of materials and do not buy from a photograph alone. The correct screening choice depends on the circuit and the connected equipment's EMC instructions.
Select a cable as an exact article within a complete electrical and mechanical installation. Record conductor size and count, protective-conductor arrangement, screening, jacket, length and the actual termination hardware. Outer diameter affects glands and routing. Flexibility during installation, repeated bending and torsion are different requirements, so choose the documented duty rather than inferring it from the feel of a sample.
Configuration and Integration

Oil resistance is relevant to machinery environments, but the actual exposure still needs review. Identify coolant or cleaning chemistry, contact duration and temperature rather than interpreting the family description as resistance to every industrial fluid. A matched cable gland also depends on the actual outer diameter and assembly, not just a shared manufacturer name.
Prepare a cable schedule that links each circuit to its ordered article, endpoints and routing. Check termination compatibility, identification, strain relief and any required shield connection. Follow the selected cable and equipment instructions for bend radius, support and environmental conditions. A cable specification does not replace the design of circuit protection, grounding or the connected machine.
Applications and Use Cases
Consider the exact OLFLEX 190 article for a defined machine or control-panel cable route with known circuit and environmental requirements. Verify the current datasheet and physical marking before specifying an industrial replacement.
For a maintained machine, record the complete cable reference and termination arrangement before replacement. Match the required circuit function and installed markings, then inspect the route for abrasion and unsupported loading. A newer catalog reference or changed conductor population can alter outer diameter and fit even when the general cable-family label remains unchanged.
Judge the installed cable by its electrical function, routing and maintenance requirement. A family description helps identify candidates; conductor size, installation conditions and the actual duty determine whether a particular article is suitable. A component marking does not independently certify an entire machine or every possible installation method.
Alternatives and Selection
Compare OLFLEX 190 with 190 CY when screening is required, and with a documented continuous-flex cable when the route moves repeatedly. Use the same circuit, exposure, termination and motion requirements in the comparison.
Price and Value
Price: Request a quote. The quotation should identify the exact product configuration, included options, delivery terms and support scope. Accessories and integration work should be listed separately so the hardware price can be compared on a like-for-like basis. A family name or headline specification is not a complete purchasing description.
Assess value against the work the product enables in the machine. Include the engineering needed to configure it, the equipment that must operate alongside it and the effort required to maintain or replace it. A lower component price can be outweighed by extra integration work, while additional features are valuable only when the application can use them. Compare written configurations rather than assumed package contents.
Pros and Cons
Pros
Oil-resistant construction addresses an identified industrial exposure requirement
Multi-conductor family supports specified power and control circuits
Shielded companion is available when the design requires it
Cons
190 and 190 CY are different screening configurations
Family name does not establish exact diameter or conductor population
Continuous-motion suitability requires separate documented confirmation
Who Should Consider LAPP OLFLEX 190 Industrial Control Cable?
Evaluate OLFLEX 190 for an industrial control or power route that matches the exact article's electrical, environmental and installation limits. Select shielding deliberately, and do not treat installation flexibility as evidence of a continuous-motion duty rating.
The strongest purchasing case is a clearly defined requirement that matches the documented configuration. If the project depends on a particular option, interface or mechanical arrangement, include it explicitly in the order. Keep the accepted configuration with the equipment documentation so a later replacement preserves the intended application.
Commissioning and Acceptance
Verify the delivered article and jacket markings against the cable schedule before installation. Inspect routing, termination, support, separation and strain relief using the approved electrical procedure. Where movement is required, qualify the representative machine cycle within the documented limits. Keep article identities and replacement lengths with maintenance records, and reassess the affected route when the equipment or motion changes.
LAPP OLFLEX 190 Industrial Control Cable FAQ
What is LAPP OLFLEX 190 Industrial Control Cable?
OLFLEX 190 is LAPP's oil-resistant multi-conductor power and control cable family for industrial equipment. The unshielded 190 and shielded 190 CY are separate choices; conductor configuration and installation ratings must be checked by article number.
Which configuration is reviewed?
Reviewed family: OLFLEX 190 industrial power and control cable. Jacket reference: Oil-resistant PVC family construction.
What is the main selection consideration?
Evaluate OLFLEX 190 for an industrial control or power route that matches the exact article's electrical, environmental and installation limits. Select shielding deliberately, and do not treat installation flexibility as evidence of a continuous-motion duty rating.
What applications should it be considered for?
Consider the exact OLFLEX 190 article for a defined machine or control-panel cable route with known circuit and environmental requirements. Verify the current datasheet and physical marking before specifying an industrial replacement.
What is a documented advantage?
Oil-resistant construction addresses an identified industrial exposure requirement. Multi-conductor family supports specified power and control circuits.
What limitation matters during integration?
190 and 190 CY are different screening configurations. Family name does not establish exact diameter or conductor population.
What is the price?
Price: Request a quote. Specify the exact ordering configuration, required options, accessories and delivery terms.
How should an alternative be compared?
Compare OLFLEX 190 with 190 CY when screening is required, and with a documented continuous-flex cable when the route moves repeatedly. Use the same circuit, exposure, termination and motion requirements in the comparison.
Product information: LAPP OLFLEX 190 article pages and the LAPP-authored directory description distinguishing 190 from 190 CY.
Pricing is quotation-based and may change. Options, availability, delivery and application requirements depend on the selected ordering configuration.