Quick Verdict
The wired KeTop T150/T155 family is useful when mobile operator access and a defined connection point fit the machine. Select the complete terminal, cable, connection box and software image; a general IPC or Windows reference should not be treated as a universal current configuration.
KEBA KeTop T150 and T155 Wired Mobile HMI at a Glance
Product identity: KeTop T150 portrait and T155 landscape; wired family reviewed here
Operator interface: Capacitive multitouch with configured keypad and operator-control arrangements
Connection scope: Compatible wired cable and connection-box configuration required
Software scope: Supported native, browser or remote visualization depends on the ordered hardware/software image
Protective controls: Exact emergency-stop and enabling configuration must match its installation and qualification
Environmental reference: Supplied listing states IP65; confirm the complete terminal/connection arrangement and current instructions
Price: Request a quote for the exact ordering configuration.
Technical Specifications
Specification | Documented configuration |
Product identity | KeTop T150 portrait and T155 landscape; wired family reviewed here |
Operator interface | Capacitive multitouch with configured keypad and operator-control arrangements |
Connection scope | Compatible wired cable and connection-box configuration required |
Software scope | Supported native, browser or remote visualization depends on the ordered hardware/software image |
Protective controls | Exact emergency-stop and enabling configuration must match its installation and qualification |
Environmental reference | Supplied listing states IP65; confirm the complete terminal/connection arrangement and current instructions |
Design and Build
Portrait and landscape options change how the operator holds and reads the device. Evaluate the intended screens and physical input arrangement at the machine, particularly for teach-in and maintenance tasks. The family picture shows possible terminal forms rather than every option supplied together. The full order should identify housing orientation, input devices and the compatible cable and connection-box arrangement.
A mobile HMI should be selected as an operator device with a defined display, input arrangement, connection system and mounting or storage provision. Evaluate the actual gloves, viewing position and reach needed during the task. The display size alone does not establish usable controls or suitable ergonomics. Specify the required emergency-stop and enabling arrangement as part of the complete ordered configuration.
Configuration and Integration

The source refers to Windows 10, HTML5 and optional Linux, while current manufacturer material describes several visualization arrangements. Those references should become a supported software definition for the actual terminal rather than an assumption that every operating environment ships together. Specify the exact image, HMI runtime or remote client, controller compatibility and maintenance baseline. For a legacy image, confirm the present support and restoration plan.
Define the interface between visualization, ordinary machine commands and protective functions. Each should have a clear role in the machine architecture and a documented behavior when communication or power becomes unavailable. Preserve the HMI image, application project, connection configuration and compatible controller releases together. A screen that connects successfully is only the beginning of application acceptance.
Applications and Use Cases
Relevant to a specified machine or robot operation task that benefits from a mobile wired HMI. Confirm the terminal variant, connection hardware, software support and approved protective configuration.
Emergency-stop and enabling devices are part of the complete machine architecture. Their presence on the housing does not validate the configured protective function or make ordinary HMI commands protective. Define operation at the connection point and the behavior when the pendant is connected, disconnected or unavailable. Validate the real operator sequence and approved protective response, then preserve the device identity and accepted software and wiring with the machine record.
The relevant result is understandable and controlled operator interaction at the machine. An HMI can display several systems without automatically owning their control logic or satisfying their protective requirements. Confirm the supported software and host arrangement for the exact terminal.
Alternatives and Selection
Compare the wired T150/T155 with the matched Safe Wireless family and a fixed operator panel using the same tasks and host software. Include connection equipment, service access and protective integration in the decision.
Price and Value
Price: Request a quote. The quotation should identify the exact product configuration, included options, delivery terms and support scope. Accessories and integration work should be listed separately so the hardware price can be compared on a like-for-like basis. A family name or headline specification is not a complete purchasing description.
Assess value against the work the product enables in the machine. Include the engineering needed to configure it, the equipment that must operate alongside it and the effort required to maintain or replace it. A lower component price can be outweighed by extra integration work, while additional features are valuable only when the application can use them. Compare written configurations rather than assumed package contents.
Pros and Cons
Pros
Portrait and landscape arrangements support different operator tasks
Multitouch and configured physical inputs provide flexible interaction
Wired connection supports a defined terminal-to-machine installation
Cons
Family options require a complete terminal/cable/connection-box order
Software and operating-system support depend on the actual image
Protective controls require complete-system integration and validation
Who Should Consider KEBA KeTop T150 and T155 Wired Mobile HMI?
The wired KeTop T150/T155 family is useful when mobile operator access and a defined connection point fit the machine. Select the complete terminal, cable, connection box and software image; a general IPC or Windows reference should not be treated as a universal current configuration.
The strongest purchasing case is a clearly defined requirement that matches the documented configuration. If the project depends on a particular option, interface or mechanical arrangement, include it explicitly in the order. Keep the accepted configuration with the equipment documentation so a later replacement preserves the intended application.
Commissioning and Acceptance
Test the intended operator tasks with the actual controller and application. Verify startup, device identification, interrupted communication and restored configuration, along with the separately approved protective-function checks. Confirm what the operator sees and can command in each state. Maintain the accepted software image and complete device identity so replacement equipment reproduces the approved operation.
KEBA KeTop T150 and T155 Wired Mobile HMI FAQ
What is KEBA KeTop T150 and T155 Wired Mobile HMI?
KEBA KeTop T150 and T155 are mobile HMI families with portrait and landscape arrangements, multitouch operation and configuration-dependent operator inputs and safety connections for a defined machine-control system.
Which configuration is reviewed?
Product identity: KeTop T150 portrait and T155 landscape; wired family reviewed here. Operator interface: Capacitive multitouch with configured keypad and operator-control arrangements.
What is the main selection consideration?
The wired KeTop T150/T155 family is useful when mobile operator access and a defined connection point fit the machine. Select the complete terminal, cable, connection box and software image; a general IPC or Windows reference should not be treated as a universal current configuration.
What applications should it be considered for?
Relevant to a specified machine or robot operation task that benefits from a mobile wired HMI. Confirm the terminal variant, connection hardware, software support and approved protective configuration.
What is a documented advantage?
Portrait and landscape arrangements support different operator tasks. Multitouch and configured physical inputs provide flexible interaction.
What limitation matters during integration?
Family options require a complete terminal/cable/connection-box order. Software and operating-system support depend on the actual image.
What is the price?
Price: Request a quote. Specify the exact ordering configuration, required options, accessories and delivery terms.
How should an alternative be compared?
Compare the wired T150/T155 with the matched Safe Wireless family and a fixed operator panel using the same tasks and host software. Include connection equipment, service access and protective integration in the decision.
Product information: KEBA KeTop T15x mobile-handheld manufacturer description and supplied T150/155 mobile-HMI listing.
Pricing is quotation-based and may change. Options, availability, delivery and application requirements depend on the selected ordering configuration.