top of page

EPIX 160MP Imaging System Review: Specs & Applications

Oct 13
5 min read

Updated: 7 days ago

Supplier product image accompanying the EPIX 160 Megapixel Imaging System camera listing
EPIX 160 Megapixel Imaging System: supplier product image.

EPIX's 160 Megapixel Imaging System is a published multi-camera acquisition configuration built around 16 SILICON VIDEO cameras and four PIXCI SI4 frame grabbers. It is not a single 160MP sensor. Price: Request a quote.


The camera should be selected as part of an imaging system rather than evaluated from one headline specification. The useful result is an image that reveals the required feature at the right time, followed by a reliable inspection or measurement decision. This review considers the documented acquisition package, optical implications and practical purchasing scope for 160MP Imaging System.


Quick Verdict

The published system is useful as an example of a coordinated host-based acquisition architecture rather than as a single-camera resolution upgrade. Its purchasing value depends on whether multiple views or parallel observations solve the application's problem. A current proposal should specify cameras, acquisition boards, software, workstation and recording behavior as one tested system.


160MP Imaging System at a Glance

  • Product: EPIX 160 Megapixel Imaging System

  • Image format: Sixteen separate 10C6/10M6 image streams; camera mode determines pixel format

  • Acquisition: Multi-Camera Acquisition

  • Interface: Four PIXCI SI4 frame grabbers and SILICON VIDEO cameras

  • Capture rate: Per-camera mode and workstation configuration dependent

  • Listed architecture: 16 SILICON VIDEO 10C6 or 10M6 cameras

  • Frame grabbers: 4 PIXCI SI4

  • Published workstation example: Intel Core i7; 64 GB RAM; up to 24 drives

  • System role: Continuous sequence capture or live image analysis

  • Scope: Published reference configuration; request a current system proposal

  • Price: Request a quote


160MP Imaging System Technical Specifications

Specification

Value or configuration

Product

EPIX 160 Megapixel Imaging System

Image format

Sixteen separate 10C6/10M6 image streams; camera mode determines pixel format

Acquisition

Multi-Camera Acquisition

Interface

Four PIXCI SI4 frame grabbers and SILICON VIDEO cameras

Capture rate

Per-camera mode and workstation configuration dependent

Listed architecture

16 SILICON VIDEO 10C6 or 10M6 cameras

Frame grabbers

4 PIXCI SI4

Published workstation example

Intel Core i7; 64 GB RAM; up to 24 drives

System role

Continuous sequence capture or live image analysis

Scope

Published reference configuration; request a current system proposal

Price

Request a quote


Design and Optical Requirements

Each camera needs an optical arrangement matched to its view. Consistency of image scale, focus and illumination is important if results from different views will be compared. Mechanical fixtures should preserve the relationship between cameras and objects through maintenance. Sixteen camera positions can expose features hidden from one view, but simply adding views does not establish calibrated three-dimensional measurement.


Acquisition Speed and Integration

The published architecture uses four SI4 frame grabbers for sixteen cameras. Establish how triggers, resets and capture sequences are coordinated and how the software associates every image with the correct observation. A recording test should monitor all streams, including the behavior when one expected image is missing. Recording duration depends on the selected modes and workstation rather than on the nominal system name.


Programming and Image Processing

The documented capabilities include multi-camera image acquisition, sequence capture, camera reset control, image processing with the selected software. Use those controls to establish a repeatable acquisition recipe for the station. Determine which adjustments are performed in the camera and which belong in the host software. Store the chosen settings with the inspection configuration so an operator or service technician can reproduce the image used during commissioning. A parameter change should be evaluated against both good and faulty samples before it becomes the production default.


Image Data and Host Capacity

Size the workstation from the sum of the active image streams. Each camera's chosen dimensions, output representation and capture rate contribute to the total memory and storage load. A system with sixteen cameras does not automatically produce one stitched image; stitching, calibration or view association is a separate application requirement. Define the recording duration and retained data format before sizing the storage array, then validate all streams together under realistic processing and disk activity.


160MP Imaging System Applications and Use Cases

Potential uses include multi-view inspection and parallel laboratory observation when the selected camera and host configuration satisfy the acquisition requirements. The supplier's reference describes continuous capture or live analysis. Define whether the application needs synchronized views, independent observations or a stitched result; each creates a different software and calibration requirement.


Building a Useful Acceptance Trial

Prepare representative parts or scenes that include the smallest required feature, normal production variation and realistic faults. Confirm the field of view and exposure before tuning the inspection. Record wrong accepts, wrong rejects, missing frames and the complete trigger-to-decision timing. A trial should also show what happens when the expected image is absent or unusable. This connects camera selection to the station's actual acceptance requirement rather than relying on a sharp reference picture.


160MP Imaging System Price and Value

Price: Request a quote. Ask for the complete 160 Megapixel Imaging System ordering code and an itemized scope covering the camera, suitable optics, receiving hardware, cables, power and commissioning. Compare quotations for the same image format, acquisition mode and integration scope. The cost of a camera component is different from the cost of a working inspection station. Evaluate any financial return with the plant's actual labor, defect, rework and maintenance data; no universal payback period follows from these specifications.


Comparison and Selection

A single high-resolution camera captures one optical view. This EPIX arrangement captures multiple views using separate sensors and receiving boards. The practical comparison is whether more viewpoints or more detail within one viewpoint solves the problem. The 15C5 is a separate EPIX camera, while EPIX's current systems portfolio also includes other multi-camera configurations.


Ordering, Environment and Lifecycle

The supplied configuration is a published reference rather than a guarantee of the current workstation bill of materials. Request a current proposal with supported operating system, drivers, storage and camera ordering codes. A long-lived installation needs a support plan for cameras, acquisition boards and workstation software together.


Pros and Cons

Pros

  • Documented multi-camera architecture.

  • Camera, capture-board and workstation scope can be specified together.

  • Multiple views can address an application that one optical view cannot cover.


Cons

  • Synchronization and view association require application design.

  • Sixteen streams impose substantial host and storage requirements.

  • The published reference workstation should not be assumed to be the current supplied configuration.


Who Should Buy 160MP Imaging System?

Shortlist 160MP Imaging System when its documented sensor, interface and acquisition mode match the imaging task and the team can demonstrate the complete host pipeline. Use the sample trial to establish whether the relevant features remain distinguishable under the expected lighting, presentation and motion. Before purchase, settle the optical configuration, ordering variants and support requirements. The best choice is the configuration that satisfies the acceptance criteria with a maintainable system architecture.




160MP Imaging System FAQ

Is this one 160MP camera?

No. The published architecture includes sixteen SILICON VIDEO cameras and four PIXCI SI4 receiving boards.


Which cameras are listed?

The reference names SILICON VIDEO 10C6 color or 10M6 monochrome cameras. The exact current configuration belongs in the quotation.


Does it create a single stitched image?

That should not be assumed. The capture architecture supplies separate images; stitching or spatial reconstruction needs its own software and calibration.


What determines capture rate?

The camera mode, receiving hardware, workstation load and recording settings determine the usable capture behavior.


How much memory is in the published reference?

The supplier's published example lists 64 GB RAM. A new system should be sized from its actual acquisition requirements.


Can it record for hours?

The supplier describes long continuous capture as a use of the reference system. Achievable duration depends on the selected modes and storage configuration and should be demonstrated in the proposal.


What is the price?

Price: Request a quote for the complete current acquisition-system scope.


What should acceptance testing include?

Capture all configured streams together and check synchronization, missing-image behavior, retained sequences and the intended processing under realistic workstation load.


Price: Request a quote. Final configuration, pricing, availability and support terms depend on the supplier's current quotation.


FAIRINO ROBOTIC ARM_edited_edited_edited_edited.png
All Things Cobots

Free Consultation

ROBOTIC ARMS
All Things Cobots

© All Things Cobots Proudly created By G2T

bottom of page