top of page

Chromasens allPIXA wave 10K Review: Specs & Applications

Oct 13
5 min read

Updated: 7 days ago

Supplier product image accompanying the Chromasens allPIXA wave 10K camera listing
Chromasens allPIXA wave 10K: supplier product image.

Chromasens allPIXA wave 10K provides 10240-pixel RGB line acquisition. The cited R06 manual lists 25.33 kHz at full width in Full80 ten-tap 8-bit mode, with separate restricted-ROI rates. Price: Request a quote.


The camera should be selected as part of an imaging system rather than evaluated from one headline specification. The useful result is an image that reveals the required feature at the right time, followed by a reliable inspection or measurement decision. This review considers the documented acquisition package, optical implications and practical purchasing scope for allPIXA wave 10K.


Quick Verdict

The 10K wave model is a wide-field RGB line-scan camera whose usable rate depends on Camera Link configuration and retained image region. It merits evaluation when the field and smallest feature need 10240 cross-track samples. The documented full-width RGB rate should govern the initial system design, rather than a broader directory headline.


allPIXA wave 10K at a Glance

  • Product: Chromasens allPIXA wave 10K

  • Image format: 10240 spatial pixels per RGB line; constructed image height is scan dependent

  • Acquisition: Trilinear Cmos Line-Scan Acquisition

  • Interface: Camera Link; mode and tap configuration dependent

  • Capture rate: 25.33 kHz full-width RGB in cited Full80 10-tap 8-bit mode

  • Line width: 10240 pixels per RGB line

  • Pixel size: 5.6 µm

  • Color architecture: Three registered RGB sensor lines

  • ROI example: Up to 47.42 kHz for qualifying central ≤5K ROI in R06 manual

  • Rate basis: Manufacturer R06 manual mode table

  • Price: Request a quote


allPIXA wave 10K Technical Specifications

Specification

Value or configuration

Product

Chromasens allPIXA wave 10K

Image format

10240 spatial pixels per RGB line; constructed image height is scan dependent

Acquisition

Trilinear Cmos Line-Scan Acquisition

Interface

Camera Link; mode and tap configuration dependent

Capture rate

25.33 kHz full-width RGB in cited Full80 10-tap 8-bit mode

Line width

10240 pixels per RGB line

Pixel size

5.6 µm

Color architecture

Three registered RGB sensor lines

ROI example

Up to 47.42 kHz for qualifying central ≤5K ROI in R06 manual

Rate basis

Manufacturer R06 manual mode table

Price

Request a quote


Design and Optical Requirements

The 10240-pixel line requires a lens and illumination arrangement with suitable coverage and contrast over the complete width. Pixel pitch is 5.6 µm in the manufacturer datasheet. RGB registration and sampling along motion belong in the commissioning recipe. Check edge focus and normal surface or height variation using actual objects.


Acquisition Speed and Integration

The R06 manual gives 25.33 kHz for full width in its Full80 ten-tap 8-bit mode. The table lists different rates for other Camera Link modes. Its higher ROI rate applies to specified central regions and is not the full-width limit. Set the receiver tap mapping and output representation explicitly, then validate the complete scan and host processing.


Programming and Image Processing

The documented capabilities include color conversion matrix, continuous white balance, shading and offset correction, gamma correction, multiple image regions, scan synchronization. Use those controls to establish a repeatable acquisition recipe for the station. Determine which adjustments are performed in the camera and which belong in the host software. Store the chosen settings with the inspection configuration so an operator or service technician can reproduce the image used during commissioning. A parameter change should be evaluated against both good and faulty samples before it becomes the production default.


Image Data and Host Capacity

Size the chosen line width, three RGB channel values, output representation and actual scan rate as one operating point. A cropped region changes field coverage and can change cadence. Image height grows over successive scan lines, with geometry determined by transport synchronization. Budget receiver mapping, host buffers, processing and retained scans together.


allPIXA wave 10K Applications and Use Cases

Wide print, web, panel and surface inspection can merit a trial. The constructed image should preserve both RGB feature contrast and spatial geometry across transport. Include normal presentation changes and real faults. A larger line width can reduce the need for multiple views, but it still requires appropriate optics and sampling.


Building a Useful Acceptance Trial

Prepare representative parts or scenes that include the smallest required feature, normal production variation and realistic faults. Confirm the field of view and exposure before tuning the inspection. Record wrong accepts, wrong rejects, missing frames and the complete trigger-to-decision timing. A trial should also show what happens when the expected image is absent or unusable. This connects camera selection to the station's actual acceptance requirement rather than relying on a sharp reference picture.


allPIXA wave 10K Price and Value

Price: Request a quote. Ask for the complete allPIXA wave 10K ordering code and an itemized scope covering the camera, suitable optics, receiving hardware, cables, power and commissioning. Compare quotations for the same image format, acquisition mode and integration scope. The cost of a camera component is different from the cost of a working inspection station. Evaluate any financial return with the plant's actual labor, defect, rework and maintenance data; no universal payback period follows from these specifications.


Comparison and Selection

The 15K wave provides more cross-track samples but a lower documented full-width rate in the same listed receiving mode. Choose 10K when its field sampling is sufficient and the specified cadence better suits the station. Evo and pro use other acquisition architectures and should be compared through exact mode tables.


Ordering, Environment and Lifecycle

The supplied directory mentions a 150 kHz family claim, while the manufacturer R06 manual and datasheets describe lower RGB mode-dependent figures. This review follows the manual for the stated full-width mode and identifies the ROI restriction. Require the current confirmed rate, line format, receiver and firmware in the quotation.


Pros and Cons

Pros

  • 10240-pixel RGB line width.

  • Documented full-width Camera Link mode table.

  • Color and scan correction controls.


Cons

  • Higher ROI rates do not apply to full width.

  • Wide-field optics and RGB registration need validation.

  • Directory speed claims require reconciliation with current mode documentation.


Who Should Buy allPIXA wave 10K?

Shortlist allPIXA wave 10K when its documented sensor, interface and acquisition mode match the imaging task and the team can demonstrate the complete host pipeline. Use the sample trial to establish whether the relevant features remain distinguishable under the expected lighting, presentation and motion. Before purchase, settle the optical configuration, ordering variants and support requirements. The best choice is the configuration that satisfies the acceptance criteria with a maintainable system architecture.




allPIXA wave 10K FAQ

Is allPIXA wave 10K an area camera?

It uses line-scan acquisition. An area image is constructed from successive lines as the target or scan moves.


What line format is documented?

10240 spatial pixels per RGB line; this is not one area-image width-times-height specification.


What rate is documented?

25.33 kHz full width in the cited Full80 ten-tap 8-bit mode. Specify the exact current operating mode.


Is line frequency a frame rate?

No. Image height and sampling along motion determine the constructed area-image scope.


Which receiving interface is described?

Camera Link. Match receiver, output representation and control setup to the exact ordering code.


What is the main selection distinction?

Restricted ROI rates and broad directory maxima should not be assigned to the full-width RGB mode.


What is the price?

Price: Request a quote for the camera, optics, illumination, synchronization, receiver and commissioning.


What should acceptance verify?

Verify feature contrast, channel registration where applicable, spatial geometry, sustained acquisition and the actual inspection decision.


Price: Request a quote. Final configuration, pricing, availability and support terms depend on the supplier's current quotation.


FAIRINO ROBOTIC ARM_edited_edited_edited_edited.png
All Things Cobots

Free Consultation

ROBOTIC ARMS
All Things Cobots

© All Things Cobots Proudly created By G2T

bottom of page