top of page

AVAL DATA ABA-003IR-GE SWIR Camera Review

Oct 13
5 min read

Updated: 7 days ago

Supplier product image accompanying the AVAL DATA ABA-003IR-GE camera listing
AVAL DATA ABA-003IR-GE: supplier product image.

AVAL DATA ABA-003IR-GE provides a 640 × 512 image with global-shutter acquisition through GigE Vision over 1000BASE-T. Its documented frame-rate configuration is 62 fps at the listed short exposure; 31 fps at listed 16 ms exposure. Price: Request a quote.


The camera should be selected as part of an imaging system rather than evaluated from one headline specification. The useful result is an image that reveals the required feature at the right time, followed by a reliable inspection or measurement decision. This review considers the documented acquisition package, optical implications and practical purchasing scope for ABA-003IR-GE.


Quick Verdict

ABA-003IR-GE supplies a cooled SWIR image through a network receiving path. It is worth evaluating when the required material contrast lies in the documented infrared band and GigE integration suits the machine. Sensor scale, cooling and the full exposure-to-decision cycle should be specified together.


ABA-003IR-GE at a Glance

  • Product: AVAL DATA ABA-003IR-GE

  • Image format: 640 × 512

  • Acquisition: Global

  • Interface: GigE Vision over 1000BASE-T

  • Capture rate: 62 fps at the listed short exposure; 31 fps at listed 16 ms exposure

  • Sensor: Peltier-cooled InGaAs

  • Spectral band: 950–1700 nm in manufacturer release

  • Pixel size: 20 µm

  • Output: 8, 10, 12 or 14-bit

  • Lens mount: C-mount

  • Body: 58 × 58 × 115 mm, excluding protrusions

  • Price: Request a quote


ABA-003IR-GE Technical Specifications

Specification

Value or configuration

Product

AVAL DATA ABA-003IR-GE

Image format

640 × 512

Acquisition

Global

Interface

GigE Vision over 1000BASE-T

Capture rate

62 fps at the listed short exposure; 31 fps at listed 16 ms exposure

Sensor

Peltier-cooled InGaAs

Spectral band

950–1700 nm in manufacturer release

Pixel size

20 µm

Output

8, 10, 12 or 14-bit

Lens mount

C-mount

Body

58 × 58 × 115 mm, excluding protrusions

Price

Request a quote


Design and Optical Requirements

The active sensor grid and 20 µm pixels determine object-space sampling after magnification. A C-mount lens needs adequate SWIR transmission and focus; the mount alone does not establish optical suitability. Test actual material thickness, finish and illumination across 950–1700 nm. Stabilize the selected thermal and correction settings before comparing response.


Acquisition Speed and Integration

The published family timing links rate to exposure: 62 fps at a short exposure and 31 fps at 16 ms exposure. Specify the actual pixel representation, network configuration and SDK before sizing the host. A triggered exposure event does not establish the complete result latency. Observe image availability during realistic processing and network activity.


Programming and Image Processing

The documented capabilities include external triggering, internal cooling, defective-pixel correction, shading correction, lookup tables, programmable pixel representation. Use those controls to establish a repeatable acquisition recipe for the station. Determine which adjustments are performed in the camera and which belong in the host software. Store the chosen settings with the inspection configuration so an operator or service technician can reproduce the image used during commissioning. A parameter change should be evaluated against both good and faulty samples before it becomes the production default.


Image Data and Host Capacity

As an engineering estimate, a 640 × 512 frame represented as one uncompressed 8-bit value per pixel contains about 0.33 MB of pixel data, using decimal megabytes. This excludes transport overhead and metadata. It is a sizing example, not a measured camera transfer rate; other output representations change the data volume. Multiply the selected frame size by the planned acquisition rate when budgeting host memory, processing and storage, then validate the complete pipeline under realistic load.


ABA-003IR-GE Applications and Use Cases

Inspection of materials, glass-related features or semiconductor scenes can merit a representative spectral trial. Prove the required distinction against normal composition and surface variation. An infrared image does not by itself establish a chemical measurement, medical approval or certified quality decision.


Building a Useful Acceptance Trial

Prepare representative parts or scenes that include the smallest required feature, normal production variation and realistic faults. Confirm the field of view and exposure before tuning the inspection. Record wrong accepts, wrong rejects, missing frames and the complete trigger-to-decision timing. A trial should also show what happens when the expected image is absent or unusable. This connects camera selection to the station's actual acceptance requirement rather than relying on a sharp reference picture.


ABA-003IR-GE Price and Value

Price: Request a quote. Ask for the complete ABA-003IR-GE ordering code and an itemized scope covering the camera, suitable optics, receiving hardware, cables, power and commissioning. Compare quotations for the same image format, acquisition mode and integration scope. The cost of a camera component is different from the cost of a working inspection station. Evaluate any financial return with the plant's actual labor, defect, rework and maintenance data; no universal payback period follows from these specifications.


Comparison and Selection

ABA-003IR-CL uses Camera Link and a different receiving and control setup. ABL-005IR is a line-scan model with different spatial and motion requirements. Choose the acquisition architecture from the actual scene and machine layout rather than combining the interface choices into one camera specification.


Ordering, Environment and Lifecycle

The detailed cited release dates from 2015. Request current availability, SDK support, power and cooling requirements. The old release lists some certifications as planned, which should not be represented as completed current certification. Confirm that the proposed GE system retains the intended output, trigger and correction behavior.


Pros and Cons

Pros

  • Cooled InGaAs imaging in the documented SWIR band.

  • Defined GigE Vision receiving path.

  • Several output bit depths and correction controls.


Cons

  • Current lifecycle and software support require confirmation.

  • SWIR optics and material contrast need testing.

  • Exposure and output representation affect acquisition timing.


Who Should Buy ABA-003IR-GE?

Shortlist ABA-003IR-GE when its documented sensor, interface and acquisition mode match the imaging task and the team can demonstrate the complete host pipeline. Use the sample trial to establish whether the relevant features remain distinguishable under the expected lighting, presentation and motion. Before purchase, settle the optical configuration, ordering variants and support requirements. The best choice is the configuration that satisfies the acceptance criteria with a maintainable system architecture.




ABA-003IR-GE FAQ

What is the native resolution of ABA-003IR-GE?

640 × 512 pixels is the documented native image format. Evaluate the optics and required feature scale alongside that pixel count.


Which shutter architecture does it use?

The documented sensor uses a global shutter. A common exposure interval across the image does not eliminate blur caused by movement during exposure.


What interface is required?

GigE Vision over 1000BASE-T is the documented acquisition interface. Match the receiving hardware and software to the exact ordering configuration.


What is the maximum frame rate?

The documented rate is 62 fps at the listed short exposure; 31 fps at listed 16 ms exposure. Confirm the specified operating mode; maximum capture rate is not a guarantee of completed inspection throughput.


Which acquisition features are documented?

The product information includes external triggering, internal cooling, defective-pixel correction, shading correction, lookup tables, programmable pixel representation. Configure the selected functions around the actual trigger and image-processing requirement.


What should be included in a system comparison?

ABA-003IR-CL uses Camera Link and a different receiving and control setup. ABL-005IR is a line-scan model with different spatial and motion requirements. Choose the acquisition architecture from the actual scene and machine layout rather than combining the interface choices into one camera specification.


How much does the camera cost?

Price: Request a quote. Include the exact camera variant, optics, receiving hardware, power, cables and commissioning.


What should be tested before ordering?

Test representative good and faulty samples, the intended optical geometry, image timing, capture diagnostics and the complete result association with each inspected part.